Jobs from the field: UPS, generators, batteries, load banks, cooling, and recycle — Texas and beyond.
Field post from Dallas — battery recycling.
UPS replacement and recycle in Phoenix.
Pre-install tech-support in Allen.
Generator preventative maintenance and load bank.
For more info on generator projects, contact him.
End user purchased the MGE UPS. The replacement needed a larger input breaker and wire. The team retrofitted the input panel, demoed a BBM safety switch, and reworked conduit. Customer back on UPS-power.
Customer had new batteries on racks to reuse and an end-of-service-life Powerware 9315. Solution reused DC disconnects, existing bypass, and batteries, and set a new, more efficient UPS module.
Healthcare client running an old Powerware 9315 at end-of-service-life. New 40kW N+1 with 3-breaker sidecar bypass. Steve K., Customer Support Engineer, on startup.
Remote-mount maintenance bypass with integral distribution breakers, make-before-break around the UPS. One of three sites for this client on a tight construction schedule.
Part of the Globe Life Park project — the new home of the Texas Rangers. Twelve (12) large UPS systems in all.
Eaton 9355, 10–30kVA three-phase. Configurable 2×2, 4×2, 4×4, or multi-module parallel if required.
Dallas client: safely shut down the UPS, re-wired, moved a remote-mount battery cabinet, then startup after relocation. Simple-looking, heavy on planning and partners.
Existing UPS was outdated and oversized. Alternative: Eaton 93PM, cost-effective and correctly sized. Electrical install by JMEG, LLC tenant-finish group and EA Electric. General contractor: Balfour Beatty.
Friday evening to Sunday afternoon: removed two aging UPS systems, replaced with two Eaton 93PM. Eaton field engineers performed startup and a load bank test. CEC on the install. Client carrying critical load by Sunday night.
Planned outage or no backup: equipment, setup, power distribution, connection to the existing electrical system, and fueling for continuous run.
Simple startup was not enough. In-depth commissioning with load banks for a Dallas/FTW-based customer — load critical regardless of kW.
Started as a small electrical system check. Became valves, insulation, and more on the chilled water distribution. CEC crew. Client back to 100% capacity.
Catastrophic failure on an older mismanaged UPS. Rented replacement UPS with batteries shipped in and swapped the same day. Then a brand-new UPS; rental returned to the supplier.
Replaced three aging Powerware Plus Series / 9315 UPS systems. Modernized equipment, reclaimed footprint, reduced energy usage.
Two Eaton 9395 1100kVA UPS added to an existing multi-module configuration. Design-build.
Added a 3rd UPS module to an existing parallel system. Austin Rig & Crate / LL Rigging received and set the equipment.
Customer had two older, less efficient UPS systems. Repair would have meant a significant parts-and-battery investment. A pair of modern UPS systems was installed instead.
ESL / EOSL: equipment may still run, but parts and service personnel are increasingly hard to source after a failure.